Insulation: Insulation Installation

Words: Jeremy DouglasQ. I’ve always stuck rigid insulation board directly against a fluid-applied air barrier material while it’s still wet, so it sticks to the backup wall. I have a job where I’ve been told I can’t do that, but instead I have to use a special clip that slides over the anchor to hold the insulation in place. Wouldn’t it be better to adhere the insulation directly to the wall?

A. Believe it or not, I’m asked this question almost every day due to the multitude of anchoring systems we see on our projects, and the need for maintaining energy performance. Let’s look at this from various perspectives.

First, whether adhered or using an anchor clip, it is imperative that the insulation remain tight to the backup wall in order to maintain its intended R-value. It is suggested that a loosely laid extruded polystyrene insulation can lose between 15 and 20 percent of its R-value if an air gap of even 1/4–3/8 inch is left. With energy code requirements demanding higher performance from our walls, the requirement of a mechanical attachment or retaining clip is becoming more prevalent.

Many anchors hold the insulation on their own or will have a retaining device, such as a large-diameter washer, integrated into the anchor itself. Other systems that don’t have this integrated piece can use a secondary retaining clip to secure the insulation prior to the brick installation, ensuring the insulation is and remains tight to the backup wall. This can be particularly useful on hook-and-eye-style anchorage systems, where even though the hook portion of the system may retain part of the insulation, construction tolerances may not keep it set tightly.

This leads us more directly to your question about adhering the insulation, or, more specifically, adhering the insulation directly to a still-wet application of a fluid-applied air barrier system. While this has been done with some regularity in the past, it is not a great idea. Just like various types of insulation, an air barrier system can only guarantee a particular performance criteria at a specific thickness. If we are embedding a sheet of insulation into an uncured fluid-applied membrane, that required thickness will likely become depleted, and therefore the system becomes non-uniform in its rate of vapor permeance. Additionally, varied thickness of the membrane will likely diminish its ability to elongate during movement or span various small cracks or voids as we depend on it to do. will also likely create curing issues with many types of air barriers, as they depend on air exposure for that process to advance.

This does not mean that adhesion of the insulation to the barrier isn’t possible, but it means we may need to reconsider how we achieve that. First, before we go about adhering the insulation panels, the air barrier must be fully cured. From here, we might employ a thin bead of a construction adhesive or sealant confirmed to be compatible with both the air barrier system and the insulation. This material must be free of any solvents in order to work with most air barriers used today. In many cases, a sealant or filler accessory for the air barrier system is a good product to look at first, as they are usually fairly inert and unlikely to cause damage to the insulation. But, as mentioned, confirm adhesion strength as well as compatibility.

Ultimately, the important thing is that the insulation panels are retained tightly to the backup wall. How that happens is really subject to field conditions and specified anchors, though we must always maintain the integrity of all adjacent systems, especially the air barrier.
The Importance of Instructor Support
April 2026

Whether you are a new or veteran masonry instructor, we all need support throughout our careers. We can never stop learning, and keeping up with ever-changing technology, materials, and installation techniques can be overwhelming alongside the everyday pr

Vibing Masonry #11: Innovative Concrete Masonry Technologies in Healthcare Design
April 2026

In the high-stakes environment of healthcare design, every material choice is a clinical decision. Architects, engineers, and facility administrators are tasked with creating spaces that are not only resilient and code-compliant but also conducive to heal

Why Termination Bars Still Matter: A Practical Look at Long‑Term Flashing Performance
April 2026

In recent discussions across the masonry industry, I have heard termination bars described as “old school.” The implication is that with modern materials, primerless peel-and-stick flashings, advanced sealants, and structural insulated sheathing, mechanic

Building Solutions: The Critical Role of Cavity Space in Masonry Moisture Control
April 2026

Long before “rainscreen” became a popular term in building science, masonry cavity walls were functioning on that very principle. A brick veneer cavity wall is designed with the expectation that water will penetrate the exterior