Standards compliance in the storm shelter and safe room industry

Words: Jonathan LamarWhether designed for residential or community use, storm shelters and safe rooms protect lives during hurricanes, tornados and other severe weather events. Although many U.S. manufacturers claim to provide storm shelters and safe rooms, the industry is surprisingly unregulated. How can developers and engineers know for certain which storm shelters and safe rooms will withstand the most severe weather and successfully protect the lives within?

The National Storm Shelter Association (NSSA) was founded in 2001 under the leadership of Dr. Ernst Kiesling, a research professor at the Texas Tech University Nation Wind Institute, to answer just this question. The first major undertaking of the NSSA was to develop an industry standard that formed the basis for the International Code Council’s (ICC) standard for storm shelters (ICC-500). Although the NSSA does not certify any shelter manufacturer or design, it does provide procedure and process to validate a manufacturer’s claim that its shelters are in compliance with the applicable standards.

The process for getting verification includes debris-impact testing and wind-pressure analysis or testing of the building components. The process also includes a third-party evaluation of the designs by professional engineers and architects that have been approved by the NSSA to ensure standards compliance. Only after these processes have been successfully completed can manufactures become Producer Members of the NSSA and affix a seal to their shelters. Fewer than 10 percent of all shelter manufacturers in the United States have achieved this voluntary process for NSSA membership.

Many manufacturers of storm shelters and storm shelter products claim to “meet or exceed” two defining documents. The ICC-500 and the Federal Emergency Management Agency’s (FEMA) 320/361 publications are almost always used by manufacturers to ensure the safety of their product. The FEMA P320 (residential) and P361 (community) documents are intended to provide guidance for engineers, architects and manufacturers. The publications include information for the design, materials, construction methods and operation of safe rooms. FEMA does not certify that any engineer, architect or manufacturer — or their products or services — are in compliance with its guidelines. Yet, many manufacturers do claim their products are “FEMA certified” or “FEMA approved.”

Certain criteria in these guidelines must be followed in order to qualify for FEMA safe room grants, but they are not regarded as standards, whereas the ICC-500/NSSA is a consensus standard. Indeed, some state and local jurisdictions in tornado- and hurricane-prone regions have mandated compliance with the ICC-500/NSSA standards. The 2015 International Building Code requires the addition of storm shelters complying with ICC-500/NSSA for certain geographic areas and building uses, such as for schools and police, fire and rescue stations.

With so many products on the market, it is important that consumers understand the claims and word usage by manufacturers such as “certified” or “approved.” The NSSA process shifts the majority of responsibility for standards compliance to the shelter manufacturer. The NSSA is a nonprofit, self-policing organization, and members are required to abide with the bylaws and code of ethics of the association and pledge to produce only those shelters that meet or exceed the standard.

This benefits developers and engineers, as well as the manufacturers, in a number of ways, including guidance for quality products, qualification for grants in certain regions, increased property values, and decreased liability. Choosing only those manufactures that have achieved NSSA membership status is the safest way for developers and engineers to assure that their choice of manufacturer is in compliance with standards.
Five Truths About Final Brick Cleandown
May 2026

Not all truths are self-evident. Sometimes they’re easy to forget or clouded with misunderstanding. The good news is these truths of final cleandown are not hard to implement on your next project to ensure successfully cleaned and beautiful new brick.

Shelf Angles and Their Impact on Wall Performance
May 2026

Shelf angles have long been a standard component in masonry construction. Installed at the slab edge, they provide support for brick veneer and are often treated as a routine detail. However, as building performance requirements evolve, particularly aroun

The Mason’s Mark: Defining the Craft Through the Trowel
May 2026

Walk onto any job site, from a custom residential chimney to a sprawling commercial block wall, and you will hear it before you see it: the distinctive ring of high-carbon steel striking masonry. The trowel is more than just a mortar scoop; it is the cond

Registration Now Open for the 2026 MCAA Midyear Meeting in San Antonio, Texas
May 2026

The Mason Contractors Association of America (MCAA) is thrilled to announce that registration is now open for the highly anticipated 2026 MCAA Midyear Meeting, set to take place in San Antonio, Texas. This exciting event is scheduled from September 13th-1