Brick/Mortar Compatibility Research Continues

Words: Bijan AalamiMany model building codes require that brick with an initial rate of absorption (IRA) greater than 30 gm/min/30 sq. in. be wetted before laying. This is to prevent the mortar from drying too rapidly. The loss of water from the mortar may result in incomplete hydration of the cement. This is thought to result in lower flexural bond strength and walls with greater water penetration.

The building codes do not differentiate between mortar cementitious materials nor mortar type. Proper wetting of the brick is difficult to achieve and is often ignored by the mason. There is no accepted method of wetting the brick.

The Brick Institute of America (BIA), the Portland Cement Association (PCA), and the National Lime Association (NLA) have joined to evaluate the performance of high IRA brick with a variety of mortar cementitious materials and mortar types. This investigation is similar to a study completed in 1995 on brick with an IRA of 5 or less. The objective of both programs is to identify those mortar materials and types which are most compatible with brick of a given IRA.

Brick selected for this study will be all 100% solid units with wire cut bed surfaces. Mortars will be mixed by proportions using cementitious materials predominant in the Chicago area. Mortar water content will be set by the mason. Tests will be run to determine typical physical properties of all materials.

Flexural unit strength will be evaluated using ASTM C1072. The combinations of materials shown in Table I will be tested. The 45 - 50 gm brick will be laid in both dry and wetted conditions.

The results of the flexural bond tests will be used to select unit/mortar combinations for ASTM E514 water penetration tests. The combination of brick and mortar types that give the highest and lowest bond strength values will be tested.

The brick with the 15 - 20 gm IRA will serve as a basis of comparison. It is the same brick used in the low IRA brick tests run earlier. Thus, this series of tests complements the earlier research.

Table I. Bond Wrench Matrix

Unit IRA gm per min per 30 sq. in. Cementitious Material and Mortar Type
Portland Cement/Lime Mortar Cement Masonry Cement
S N O S N S N
15 - 20   X   X X X X
25 - 30 X X X   X X X
45 - 50 X X X X X X X
Moisture in Masonry: A Key Concern
August 2026

As building envelopes become tighter and more performance-driven, clarity around moisture management in masonry applications is more important than ever. In masonry wall assemblies, where water penetration is expected and managed rather than eliminated, t

Revailo Upgrades to Platinum in the 2026 and 2027 MAP
August 2026

The Mason Contractors Association of America (MCAA) is thrilled to announce that Revailo will upgrade their Silver partnership to a prominent Platinum partnership for the remainder of the 2026 MAP and for the duration of the 2027 MAP.

Restoring Structural Integrity: Reinforcement in Masonry Buildings
August 2026

Masonry, as most of us in the trade know and appreciate, remains one of the most durable and time-tested structural systems in the built environment. Structures built throughout Europe and other parts of the world demonstrate that a masonry building is mo

Designing High-Performance Masonry Envelopes: Selecting the Right Air Barrier System
August 2026