Brick/Mortar Compatibility Research Continues

Words: Bijan AalamiMany model building codes require that brick with an initial rate of absorption (IRA) greater than 30 gm/min/30 sq. in. be wetted before laying. This is to prevent the mortar from drying too rapidly. The loss of water from the mortar may result in incomplete hydration of the cement. This is thought to result in lower flexural bond strength and walls with greater water penetration.

The building codes do not differentiate between mortar cementitious materials nor mortar type. Proper wetting of the brick is difficult to achieve and is often ignored by the mason. There is no accepted method of wetting the brick.

The Brick Institute of America (BIA), the Portland Cement Association (PCA), and the National Lime Association (NLA) have joined to evaluate the performance of high IRA brick with a variety of mortar cementitious materials and mortar types. This investigation is similar to a study completed in 1995 on brick with an IRA of 5 or less. The objective of both programs is to identify those mortar materials and types which are most compatible with brick of a given IRA.

Brick selected for this study will be all 100% solid units with wire cut bed surfaces. Mortars will be mixed by proportions using cementitious materials predominant in the Chicago area. Mortar water content will be set by the mason. Tests will be run to determine typical physical properties of all materials.

Flexural unit strength will be evaluated using ASTM C1072. The combinations of materials shown in Table I will be tested. The 45 - 50 gm brick will be laid in both dry and wetted conditions.

The results of the flexural bond tests will be used to select unit/mortar combinations for ASTM E514 water penetration tests. The combination of brick and mortar types that give the highest and lowest bond strength values will be tested.

The brick with the 15 - 20 gm IRA will serve as a basis of comparison. It is the same brick used in the low IRA brick tests run earlier. Thus, this series of tests complements the earlier research.

Table I. Bond Wrench Matrix

Unit IRA gm per min per 30 sq. in. Cementitious Material and Mortar Type
Portland Cement/Lime Mortar Cement Masonry Cement
S N O S N S N
15 - 20   X   X X X X
25 - 30 X X X   X X X
45 - 50 X X X X X X X
Outreach Outlook: Springing into Action – The Season of Growth
March 2026

There is a distinct shift in the air when March arrives. You can feel it on the job sites, and you can certainly feel it in the classrooms. As the winter chill begins to lift and the days are a little longer, the construction industry naturally wakes up f

Chairman's Message: Laying the First Brick - A Fresh Start
March 2026

As we head into a new year, I’m excited and, honestly, grateful to step into the role of Chairman of the Mason Contractors Association of America. This industry has been good to my family, and I see this role as a chance to give back and help move things

GEN NXT: 2026 Skills Challenge Winners
March 2026

After another successful year of the Skills Challenge, the MCAA had the opportunity to speak with the three 1st Place winners of each skill level. Get to know their journeys, motivations, and the mindsets they have in order to compete in a national compet

2026 World of Concrete Recap
March 2026

The 2026 World of Concrete Convention marked another successful year for masonry. From the world-renowned Skills Challenge and Fastest Trowel on the Block competitions to the new innovative GEORGE AI class, we gained a lot of ground in pushing this indust