Brick/Mortar Compatibility Research Continues

Words: Bijan AalamiMany model building codes require that brick with an initial rate of absorption (IRA) greater than 30 gm/min/30 sq. in. be wetted before laying. This is to prevent the mortar from drying too rapidly. The loss of water from the mortar may result in incomplete hydration of the cement. This is thought to result in lower flexural bond strength and walls with greater water penetration.

The building codes do not differentiate between mortar cementitious materials nor mortar type. Proper wetting of the brick is difficult to achieve and is often ignored by the mason. There is no accepted method of wetting the brick.

The Brick Institute of America (BIA), the Portland Cement Association (PCA), and the National Lime Association (NLA) have joined to evaluate the performance of high IRA brick with a variety of mortar cementitious materials and mortar types. This investigation is similar to a study completed in 1995 on brick with an IRA of 5 or less. The objective of both programs is to identify those mortar materials and types which are most compatible with brick of a given IRA.

Brick selected for this study will be all 100% solid units with wire cut bed surfaces. Mortars will be mixed by proportions using cementitious materials predominant in the Chicago area. Mortar water content will be set by the mason. Tests will be run to determine typical physical properties of all materials.

Flexural unit strength will be evaluated using ASTM C1072. The combinations of materials shown in Table I will be tested. The 45 - 50 gm brick will be laid in both dry and wetted conditions.

The results of the flexural bond tests will be used to select unit/mortar combinations for ASTM E514 water penetration tests. The combination of brick and mortar types that give the highest and lowest bond strength values will be tested.

The brick with the 15 - 20 gm IRA will serve as a basis of comparison. It is the same brick used in the low IRA brick tests run earlier. Thus, this series of tests complements the earlier research.

Table I. Bond Wrench Matrix

Unit IRA gm per min per 30 sq. in. Cementitious Material and Mortar Type
Portland Cement/Lime Mortar Cement Masonry Cement
S N O S N S N
15 - 20   X   X X X X
25 - 30 X X X   X X X
45 - 50 X X X X X X X
Is Contact with Wet Mortar or Grout Dangerous?
April 2026

In the world of masonry, few materials are as common as mortar and grout. Whether you are laying brick, concrete masonry units (CMU), or pouring grout into masonry walls, wet cement and mortar are constant companions. However, beneath their utility lies a

The Importance of Instructor Support
April 2026

Whether you are a new or veteran masonry instructor, we all need support throughout our careers. We can never stop learning, and keeping up with ever-changing technology, materials, and installation techniques can be overwhelming alongside the everyday pr

Vibing Masonry #11: Innovative Concrete Masonry Technologies in Healthcare Design
April 2026

In the high-stakes environment of healthcare design, every material choice is a clinical decision. Architects, engineers, and facility administrators are tasked with creating spaces that are not only resilient and code-compliant but also conducive to heal

Why Termination Bars Still Matter: A Practical Look at Long‑Term Flashing Performance
April 2026

In recent discussions across the masonry industry, I have heard termination bars described as “old school.” The implication is that with modern materials, primerless peel-and-stick flashings, advanced sealants, and structural insulated sheathing, mechanic