Glass Block: Glass Block Makes a Comeback

Words: David Abel
Photo courtesy of Seves Glass Block.
Photo courtesy of Seves Glass Block.

Glass unit masonry has been used more frequently in the last few years for several good reasons. It offers various levels of light transmission into buildings and, depending on the pattern or color in the glass block, can also provide more privacy than conventional windows. Glass block are low maintenance, durable and provide energy efficiency comparable to double pane windows.

Glass block are traditionally laid with a relatively dry Type S or N mortar since the glass doesn’t wick any moisture from the mortar. The panels are reinforced at a maximum of 16 inches on center with joint reinforcing consisting of two W1.7 side rods with welded W1.7 cross rods. Glass block panels are laterally restrained using panel anchors at 16 inches on center along the top and sides of the panel and an asphalt emulsion isolation joint at the sill.

There are several proprietary systems that provide similar performance to the more traditional glass block construction. These systems typically use U-shaped channels installed around the perimeter of the opening for lateral restraint and use joint spacers and specialized sealants to reinforce and bond the units to create the panel. After the sealants have cured, product-specific grouts are used to fill the joints between glass units in a manner similar to grouting ceramic tile.

Sizes

Glass block come in a variety of nominal sizes including (in inches): 4 x 8, 6 x 6, 6 x 8, 8 x 8 and 12 x 12. Two thicknesses of 3 inch (thin) and 4 inch (standard) are available with the standard units typically used in commercial construction and the thin units generally used for interior glass block panels. The modular nature of glass block allows the use of multiple size units within a panel to create visual interest.

Code Limitations

Glass block are always non-loadbearing. This means that headers/lintels and jambs must be designed to span the opening and carry the additional vertical and lateral loads. The maximum area of an exterior glass block panel may also be limited by the design wind pressure in some locations.

For standard thickness block and a factored design wind pressure of 20 pounds per square foot, the area limit is 175 square feet by the Building Code Requirements for Masonry Structures (TMS 402). In high wind areas, the allowable area will be considerably less. It is a recommended to have a local engineer design any glass block opening larger than 50 square feet.

For thin-unit glass block panels, the code limits the maximum area to 100 square feet on exterior walls.

Construction Tips

First, ensure that the opening is the correct size (and square) and that the jambs are plumb and the sill and head are level. To verify the correct opening size, multiply the nominal unit size by the number of units and add ¼ inch. For example, an opening 4 units wide and 6 units tall utilizing nominal 8-inch units should be 32 ¼ by 48 ¼ inches. For panels exceeding 10 feet in width or height, the opening may need to be increased an additional amount to accommodate additional thermal or differential movement. The two diagonal measurements to check for square should be within 1/8 inch for typical window-sized openings.

Using Respirators for Silica Exposure
July 2025

Some in the masonry industry have expressed interest in respirator use as protection from harmful exposure to silica. This topic is of paramount importance due to its impact on our workers and the serious health effects of silica exposure. For those new t

From Bikes to Buildings: The Importance of Embracing Rainscreen Wall Designs and the New Building Codes.
July 2025

Have you ever been asked to do a project over the course of your lifetime? For example, when my kids were little, my wife asked me to assemble their bicycles. So, I opened the box, dumped out the contents, and cast aside whatever I thought was unnecessary

Laying the Foundation for Growth: Concrete Masonry Checkoff Unveils Five-Year Vision for Industry
July 2025

The Concrete Masonry Checkoff (CMC) put the finishing touches on an ambitious five-year vision for the industry, targeting a 20% increase in market share, driven by increased demand for concrete masonry products. “This is about building exquisite, enduri

Five of the Seven Chimneys Have Been Saved: Project Chimney Update
July 2025

In the wake of the devastating January wildfires that swept through Los Angeles's Pacific Palisades, a remarkable preservation effort is underway, spearheaded by Project Chimney, an initiative led by Evan Hall, founding director of the non-profit House Mu