Vertical rebar positioners

Words: Mike Ripley/Public/News/20120519070000-1.jpg" width="600" height="338" border="0" alt="Vertical rebar positioners aid the mason contractor in centering the bars in the core of the block." />
Vertical rebar positioners aid the mason contractor in centering the bars in the core of the block.
Vertical rebar positioners have been part of the masonry accessory package for many years. They add no structural value to the wall, but aid the mason contractor in centering the bars in the core of the block and also help to simplify the lapping process.

The most popular and economical positioners for vertical applications are the Figure 8 or S type and the O ring. They are installed perpendicular to the plane of the block crossing the core with the wire loops centered. Positioners are set in the mortar of the bed joint for stability and vertical spacing is about every four feet.

Placement tolerances for single rebar applications are listed in Specification for Masonry Structures (TMS 602-08/ACI 530.1-08/ASCE 6-08) under Part 3 — Execution 3.4 B.8. Working from the center point of the core you are allowed + ½ inch in the width or thickness of the wall and 2 inches along the length of the wall. This leaves you a space in the core center of 1 inch wide by 4 inches long to be code compliant for vertical applications.

Some masons install bars manually (by sight) and others with the aid of positioners but all with the risk of not meeting code. While the use of rebar positioners greatly narrows the margin of error, they also move during installation due to sitting on top of the shelf of the CMU and moving when mortar or the next course is applied.

A new trend in vertical rebar positioners has emerged to solve the movement issue during installation. Core inserted positioners, which are designed to fit 1½-inch deep, cross the core diagonally and fit tightly in the corners of the core. The core positioners perfectly position the bars in the code compliance zone and allow no movement during installation. They also have an extended tail section (safety bend) so if installed incorrectly (out of plane), the tail will extend outside the wall alerting the mason to turn it in the opposite position.

Double vertical core positioners are also available but with a different design, spacing the loops or guides closer to the face shell of the CMU. To complete the family there is a bond beam positioner that positions bars in the lower one-third of the unit and ½-inch off the inside face shell.

Take the guesswork out of rebar placement by using the core inserted positioners.
Are you in the Insulated Concrete Block business? Then FTC Rule 460 applies to you…
November 2025

If you supply, sell, or use any of these… Pre-insulated concrete block... Loose-Fill Insulation... Injectable Foam-in-Place Insulation... Foam Plastic Inserts... Then you must abide by FTC Rule 460, 16 CFR 460, which governs R-value testing and claims

MASONRY STRONG Podcast, Episode 33 Recap: Dawn Rogers, Executive Director at Arizona Masonry Council
November 2025

On this episode of the MASONRY STRONG Podcast, we're happy to be joined by Dawn Rogers from the Arizona Masonry Council to talk about her journey in the masonry industry, as well as give her insight as to what the future of the industry looks like.

HangTite Blended Cement Products Joins the 2026 Masonry Alliance Program as a Gold Partner
November 2025

The Mason Contractors Association of America (MCAA) is excited to announce that HangTite Blended Cement Products has joined the 2026 Masonry Alliance Program (MAP) at the Gold Level.

MCAA And Alan Pettingale Announce Strategic Partnership To Restore America’s Masonry
November 2025

The Mason Contractors Association of America (MCAA) has established a strategic partnership with Alan Pettingale, President and Founder of Specialized Masonry Restoration and creator of the Brick Talk Live podcast and Masonry Restoration Magazine. The par